Wire and rod
Tying, welding, galvanized, VR-1 wire. Copper M1 and aluminium A5E wire rod in coils. The basic hardware for reinforcement and electrical work.
35 SKU: low-carbon wire for tying rebar, Sv-08 welding wire, VR-1 for reinforcing meshes, galvanized for fences; copper M1 and aluminium A5E wire rod for electrical work.
Range & standards
| Type | Diameter, mm | Use | GOST |
|---|---|---|---|
| Tying wire | 0.8—6 | Tying rebar cages | 3282-74 |
| VR-1 wire | 3—5 | Reinforcing meshes | 6727-80 |
| Galvanized wire | 0.5—6 | Fences, mesh, grounding | 3282-74 |
| Welding Sv-08 | 1.2—5 | Submerged-arc welding | 2246-70 |
| Welding Sv-08G2S | 0.8—2 | MIG/MAG in CO₂ shielding | 2246-70 |
| Copper rod M1 | 8—10 | Rolling, conductors, busbars | 2112-79 |
| Aluminium rod A5E | 9 | Cable production, overhead lines | 13843-78 |
Selection guide
- Tying rebar cages — annealed black wire Ø 1—1.2 mm, low-carbon
- Reinforcing mesh in cement screeds — VR-1 Ø 4—5 mm
- Chain-link and tensioned wire fencing — galvanized Ø 1.4—2 mm
- MIG welding — Sv-08G2S Ø 1.2 mm in CO₂ shielding (universal size)
- Flexible bus conductors — copper rod M1 Ø 8 mm
Shipping documents
Factory certificate. For galvanized — zinc mass per m² or coating thickness in μm. For welding wire — chemistry and coating type (copper-coated, bare).
Storage, acceptance, transport
Coils or bundles in a covered storeroom. Welding wire — must be in sealed packaging to prevent oxidation (especially copper-coated).
FAQ
Q. What wire to use for tying rebar on site?
The standard is annealed black tying wire Ø 1.2 mm per GOST 3282. Supplied in coils. Consumption — about 5—8 kg per tonne of rebar.
Q. How does Sv-08 differ from Sv-08G2S?
Sv-08G2S contains manganese (Mn) and silicon (Si) additions. Suitable for welding under CO₂ shielding. Sv-08 — for submerged-arc welding. For most construction tasks, Sv-08G2S is the modern choice.